ETS provides interconnect and interface solutions for security systems integrators. We currently manufacture  special application relay boards and  a re-settable timer developed for the access control / alarm  industry. If you don't see what you need below, call us. In most cases, we can develop a product that will meet your needs economically.

 

   Go to ETS Main Page

   Go to Systems Integrator Specialty

      
  Products Main Page


 

 

ETS
Electronic Technical Services Inc.
211 Conchas SE
Albuquerque, NM 87123

Phone: 505-888-3923
Fax: 505-888-3926

Toll Free: 866-700-3923

E-mail:  sales1@etsnm.com

 

 

 

Made in U.S.A.    

 

Relay Boards, Timer, Universal Voltage Regulator
 

RI16  Sixteen Channel Relay
Board

16 zone relay board accepts any
voltage from 5 to 24vdc and
converts that signal into an
isolated, dry contact, normally
open output. The RI16 is
typically used to interface fire
alarm or industrial controls with
an access control or alarm
systems. The RI16 can be
ordered with EOL relay output
resistors (specify values when
ordering) to make direct connections
to supervised alarm equipment inputs.
 

  • Accepts a wide range of input Voltages from 5 to 24VDC
  • Polarity protected inputs
  • LED indicators for each
    channel.
  • 40ma current consumption per
    channel @ 5-24VDC.
  • 1 Amp relay output contact current rating @ 24VDC
  • Optional single or dual EOL resistors can be installed in the relay output contact circuit. (specify values when ordering)
  • Dimensions: W 3.00 x L
    10.00

 
E-mail or Call For Pricing



   
View  detailed data sheet. Requires
Adobe Acrobat Reader

 

 

***View Installation Instructions***

 


URM- 1, URM- 4, URM- 8 Universal
Relay Modules

The URM-X series of relay boards
offer system integrators an easy, truly
universal solution for controlling hi or
low current devices such as electric
locks, lights, sirens, etc with literally
ANY type of low voltage, dry contact or
open collector input signals.
 

  • Single or multi-zone electric lock,
    lighting control, etc.
  • Use low-current outputs from
    burglar alarms, fire alarms,
    access systems, CCTV systems,
    to control hi-current devices.
  • 5 to 24vdc power input.
  • Accepts these trigger types:
       Open collector or open drain
       Dry contact NC or NO.
       TTL or CMOS levels
       Any voltage from 3.3Vdc to
       24Vdc
  • Polarity protected power input.
  • Each channel has its own
    low-dropout 5 Volt regulator
  • 4.7K Ohm input impedance
  • 8 Amp 120VAC form C relay output.
  • Jumper selectable trigger type.
  • Jumper selectable Invert or buffer input signal for each channel.
  • European-style, easy terminate, input
    and output connectors.
  • LED status indicators for each relay.

 


E-mail or Call For Pricing



   
View  detailed data sheet. Requires
Adobe Acrobat Reader

 

 

***View Installation Instructions***

 


ULC - 1, ULC - 4, ULC - 8 Universal
Level Converters

The ULC-X series of level converters
offer system integrators an easy, truly
universal, solution for interfacing
equipment with different input and output voltage requirements. The
ULC outputs can also directly drive low
current devices such as electric
locks, strobes, etc.

  • Convert higher DC voltage levels
     to lower DC voltages.
  • Convert lower voltage levels
    to higher voltages.
  • Convert dry contact or open
    collector inputs to voltage outputs.
  • 5 to 24vdc power input.
  • Accepts these trigger types:
       Open collector or open drain.
       Dry contact NC or NO.
       TTL or CMOS levels
       Any voltage from 5Vdc to 24Vdc
  • 4.7K Ohm input impedance.
  • Up to 1 Amp 24Vdc sink / source
    outputs
  • Outputs short circuit protected with automatic re-settable fuse.
  • Jumper selectable trigger type.
  • Jumper selectable Invert or buffer
    input signal for each channel.
  • European-style, easy terminate, input
    and output connectors.
  • Dual LED status indicators for each
    channel.
  • Outputs can be set for sink only,
    source only or BOTH.


E-mail or Call For Pricing



   
View  detailed data sheet. Requires
Adobe Acrobat Reader

 

 

***View Installation Instructions***

 


SVRB - 3.3, 5, 6, 8, 9, 10, 12,
              15, 18, 24
Simple Voltage Regulator Board

The SVRB-X is a simple, low cost ,
linear voltage regulator board
designed for low current loads using higher available Voltage sources. Ideal for point of use power. It accepts regulated DC, unregulated DC or up to 24V AC power input Voltages. Available in ten different output voltages.

  • Compact size
  • Automatic short circuit and thermal shutdown.
    2 Watt power dissipation
  • 1 amp maximum current draw.
  • AC or DC (polarity insensitive)
    voltage input.
  • sticky backed tape Mounting.
  • Dimensions L1.25 x W1.0
     

E-mail or Call For Pricing



   
View  detailed data sheet. Requires
Adobe Acrobat Reader

 

 

***View Installation Instructions***

 


DS1  Door Contact Shunt Timer

The DS1 is designed for use on
egress doors (with no card
reader) equipped with magnetic
locks or strikes, a request to exit
device such as a PIR or electric
panic bar, and a door contact
switch. After an egress signal is
received, the door contact shunt
time begins. If the door is left
open, after the timer times out,
an alarm will result. If the door
closes before the timer time
ends, the timer is automatically
reset and the contact is
re-armed.
 

  • LED alarm indicator
  • N.C. dry contact alarm
    output and RTE.
  • Jumper configurable for
    momentary or maintained
    RTE signal.
  • Jumper settable for auto-reset
    timer (when door closes) or
    time-out upon an RTE.
  • Adjustable 1 minute to 20 minute timer.
  • Power input polarity protected.
  • Easy cable run
    terminations.
  • Power: 12VDC @ 20mA.
  • Dimensions: W 2.40 x
    L2.80


E-mail or Call For Pricing



   
View  detailed data sheet. Requires
Adobe Acrobat Reader

 

 

***View Installation Instructions***

 